• According to DIN EN 61810-1, DIN EN 60664-1
• Different pin configurations and pin arrangements
• Clearance and creepage distances:
contact-coil ≥ 8 mm
• Compact size, small height (horizontal model)
• OA 5651, 5661 horizontal models
• OA 5652, 5662, 5692 vertical models
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:8 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,8 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 80 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:28 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661
CT-222F 16 channel digital output/24VDC/source type/output 24VDC, the output high level is valid
Module features
the module supports 16 channels digital output, the output high level is valid, the output voltage is 24VDC.
module can drive field equipment. (relay, solenoid valve, etc.)
the internal bus of the module and field output are using opto-coupler.
the module has 16 digital output channel LED indicator light.
the module has the functions of thermal shutdown and overcurrent protection.
the module supports short circuit protection and overload protection.
Wiring:Max.1.5mm²(AWG 16)
Mounting Type:35mm Size DIN-Rail
Size:115*51.5*75mm
Weight:65g
Operation Temperature:-40~85
Protection Class:IP20
Operational Humidity:5%~95% RH(No Condensation)
Product Model:CT-222F
CANopen
Integrierter 1Q Regler
Integrierte Leistungselektronik
DC Permanentmagnetmotor
Absolute Positionserfassung (multiturn)
Lebensdauer: 2.000 h
Isolierstoffklasse: B, optional F
Schutzart: IP 42, optional bis IP 65
Umgebungstemperatur: -15°...40°C
Das neue low kost Sensormodul Steuergerät für alle AF*-Füllsicherungsüberwachung von Wannen, Schächten und Tanks im Ex-Bereich. Das DIN-Schienen-Gehäuse eignet sich im Schaltanlagenbau.
Spannungsversorgung 24 VDC ±10 % 2.5VA
Anschluss für 1 Fühler, eigensicherer Ausgang
Selbstüberwachung nach NAMUR EN107
RGB-LED Fehlerstatusanzeige
Fühlermesswertüberwachung und Wartungserinnerung
Relaisausgang mit 2 pot.-freien Umschaltkontakten
Funktionstaste Gerätealarmtest
Netz-Funktionsanzeige mit LED
Gehäuse IP 20 ohne Sockel, Dim. HxBxT 118x25x118 mm, Gewicht 0.160 kg
Ex-Ausführung SEV 21 ATEX 0523; Ex II (1) G [Ex ia Ga] IIC; CE; Gewässerschutztauglichkeit nach KVU
Zu Sensoren: AF-/LS-Serie
Caratteristica
— Motori CC a magnete permanente
— Spazzole in grafite e rame
— Carcassa del motore zincata
— Cuscinetti a sfera
— Fori di montaggio secondo le norme DIN 42016
Dati generali
— Durata appros.: 3000 h
— Carico max sullalbero: assiale 40 N
— Carico max sullalbero: radiale 100 N
— Classe d'isolamento: DIN VDE 0530, E
— Classe di protezione: DIN VDE 0530, IP 40
— Soppressione RFI: fattibile
AC/DC:DC
Tipo:sincrono
Tensione:10 V...50 V,5V
Altre caratteristiche:a magneti permanenti
Integrating sphere detector for Laser power in W.
Features: 50 mm dia, 10 mm dia port, synthetic ODM98 coating, 400 nm - 1100 nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate
• According to DIN EN 61810-1, DIN EN 60664-1
• Low rated power consumption
• 2 changeover contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
• Adjustment to customers specification
• Compact size, small height (at horizontal model)
• OA 5661.12 horizontal mounting
• OA 5662.12 vertical mounting
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:6 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,4 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 70 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:37 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661.12
• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching safety because of gold plated double contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High thermal continuous current
• Voltage range 0.75 ... 1.2 UN
• 15.5 mm height
Function:Safety relays with double contacts
Type of relay:monostabil
Contact material:AgNi + 5 µm Au
Continuous current:5 A
Nominal voltage UN DC:6 - 110 V
Voltage Range UN:0,75 - 1,2 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:5,5 mm
Temperature range (- / +):40 - 80 °C
Protection type:RT III (wash-tight)
Size L x W x H:46,5 x 22 x 15,5 mm
Approvals:TÜV; cRUus
Relay type:OA 5621_D